What we need to make sure is that the Revision of the CPU is a minimum Rev O.2. Please include what you were doing when this page came up and the Cloudflare Ray ID found at the bottom of this page. Today I am having a Pentair variable speed pump installed. 6700 REV C on Jandy Remote RS4 RS6 RS8 or Power Center? Feeling Great. Posted: 4/10/2016, ACTUATOR HANDLE OSCILLATES - If you see the handle on your Actuator oscillating back and forth, it may be that the Actuator's two O-rings are not lubricated sufficiently. Troubleshooting considering Jandy heat pump (as any other) is a necessary thing. This blog by FixYourBoard.comto help troubleshoot your Jandy/Blue Haven pool system. Checked breakers in the house and at the pool control center: good. The LCD display will show COIL SENSOR on the top line and MALFUNCTION on the bottom line until the problem is resolved. The IQ30-A contains Wi-Fi communication enhancements making it easier to connect iAquaLink 3.0 to home Wi-Fi networks. IQ30-A WiFi bands: 802.11 B,G, N at 2.4Ghz. The LCD display will display LOW REFRIGERANT on the top line and PRESSURE on the bottom line for the duration of the fault condition. Wow the actuator is now doing what it is supposed to do. Heater is condensing. First at startup everything was fine then All button controller all lights came on and stayed on. *Returns are not accepted on this or any other electronic item. JANDY AQUALINK RS INSTALLATION MANUAL Pdf Download Yes, that was where I found the problem. Complete Control Global, 24/7 control of any device connected to the AquaLink System. The actuator not running could be a failure of one of the stop switches. I have an older Goldline GVA-24V, Model JVA2440. Check for water level in the pool. I cut the power line for the value to the box. Jandy AE-Ti Heat Pump Troubleshooting. Jandy iAquaLink 3.0 Network Interface Module (WiFi Antenna) - IQ30-A. Is there a way to attach/send a photo? Fan running slow or premature fan failure. There are several actions that could trigger this block including submitting a certain word or phrase, a SQL command or malformed data. The pump is leaking water between the motor and pump body. I have the TruClear SWG with the power pack, VS flopro 1.65 pump with JEP R controller, and CS cartridge filter, no automation (standard timer). 5. A. Flue product moisture will condense at the start-up until the heater water temperature reaches the normal operating conditions. Main Menu. Check valve positions. When the POOL or SPA temperature chills to 50F or below there could be safety risks for anyone in the water. All button control panel (22 pages) Lighting Equipment Jandy AquaLink RS Installation Manual. (clear web browser cache & reload aqualinkd). Verify that skimmer baskets, pump basket and other screens are clean. Reset breaker or check fuse. How do I check the voltage at the actuator. Pool & Spa Automation Systems | Jandy The AquaLink RS OneTouch commands 32 auxiliaries, filtration systems, chemical automation, precision temperature settings, pump speeds, diagnostics, and multiple mood settings for onetouch convenience in a simple, menudriven system. Optional surge suppression kit/pool and spa automation (8 pages) Control Panel Jandy AquaLink RS Installation Manual. Lean fuel/air mixtureToo much combustion air. Any suggestions, instructions for how to enable JavaScript in your web browser, How To Maintain a Goldline/Hayward Pool Valve Actuator, Hayward / Goldline Valve Actuators Parts Diagram. The ON LED will flash once every 2 seconds. The IQ20-A is the replacement for the old IQ900. The voltage must be within 10% of the motor's data plate rating. Try unplugging all the JVA first then try and see if it blows, Hello , This is an inactive thread. Switch on the circuit breaker to the pump motor. Jandy AquaLink PDA does not work and says Waiting. How can - JustAnswer Transformer: https://amzn.to/2YPzL4HAnd make sure you subscribe to my channel!DISCLAIMER: Links included in this description might be affiliate links. My valve turns fully but does not close off completely. A. Identify and correct loose wiring connections, or problems with igniter, flame sensor, gas valve, or ignition control. Identify and correct cause of overheating. Your client had incorrect information. Control pump, heater, cleaner, lights, and water features from your phone. We just got our pool replastered. Identify and repair incorrect supply pipe size or pipe line blockage. Check temperature rise according to Section 7.8 of this manual. AquaPure is a salt chlorine generating system used to sanitize your pool, using a closed-loop water-softening system. If you are experiencing pool control issues, send in your Remote and Power Center (images below). Inspect vent for obstructions or blockages. Product support is not provided to homeowners. My ON1/OFF/ON2 switch is difficult to move and I think it needs to be replaced. Posted: 8/12/2019, InyoPools Product Specialist Matt S. Increase offset gas pressure by rotating the adjustment, Decrease offset gas pressure by rotating the adjustment. Occasionally your GVA-24 Goldline/Hayward Pool Actuator will malfunction. 0:00 / 5:21 Jandy Power Center not turning on PatriotMarine 3.25K subscribers 5.4K views 2 years ago Jandy Power Center won't turn on: Disconnect the transformer PCB. This feature also remains active when the control calls for chill through a remote thermostat. Register Product Warranty Policy The LCD display will show WATER SENSOR on the top line and MALFUNCTION on the bottom line until the problem is resolved. It does not support 802.11 AC (Wi-Fi 5) or 802.11 AX (Wi-Fi 6). Check blower inlet grill for obstruction. Can it be replaced? Page 17 T5 and T6 on the control panel NOTE To program the Heat Pump control panel, refer printed circuit board (PCB), located on the back to the Jandy AE Series Heat Pump Manual. Posted: 5/10/2017, InyoPools Product Specialist Dennis R. Gas pressure on heater manifold, should be adjusted to 2.5" W.C. (Natural), 9.0" W.C. (Propane). My actuator turns, but not all the way to where it usually stops. You can email the site owner to let them know you were blocked. Ensure that there is adequate room around the motor to circulate air and keep motor cool. When I reprogramed the spa, it does not show the proper response. Faulty wiring or connection. True Light Pools, LLC 3.6K subscribers Subscribe 35K views 6 years ago PLEASE SUBSCRIBE for more. The only way to shut the pump off is to shut off the power. Verify cold air is blowing out the top of the heat pump. Matt h - Your actuator may be in manual mode - step 2 of this guide. Posted: 7/5/2020, InyoPools Product Specialist Matt S. Thanks. A. It still works but my network gear no longer supports the legacy 802.11b standard required by the IQ900-A. Then tighten the Locking Knob. 3.15 amp is blown. If you have a Digital Multi Meter (DMM)/Digital Volt Meter (DVM) that can measure electrical resistance, ruling out the wiring is easy. Replace vent temperature limit switch. Either way, edit the web config, uncomment the solar heater line. You are using an out of date browser. It may have to be replaced. Not shocked properly upon startup. Rich fuel/air mixture Hi manifold pressure. The water flow switch opens creating a fault and the heat pump shuts off. For a better experience, please enable JavaScript in your browser before proceeding. Flue product moisture will, condense at the start-up until the heater water. Posted: 4/10/2019, InyoPools Product Specialist Matt S. If reset does not work and the ribbon connectors are all good then you would need to replace the indoor controller. Ensure sensor is connected correctly into the PIB PCB. What causes this and how to fix. Installation and Operation Manual ePump - Zodiac Pool Systems 4. I read this forum a nd was looking for switches to buy to change. Back of Jandy Aqualink Remote: be sure to send the board and panel in for repair. Yes, this is the latest revision iAqualink 2.0 Network interface module. If you do see the power to the Actuator, the motor in your Actuator may have failed and will have to be replaced. GVA 24 - the valve is rotating correctly but 180 degrees out of phase. This page lists all the parts replaceable on the Hayward actuator: My actuator was not turning open or close according to set temperature on Aqua Star control box. If water is at normal level, turn off pump. It may not display this or other websites correctly. Breaker or fuse may be tripped. Thanks so much! In your original post you said jandy rs it lights up the light. The iAquaLink IQ20-A is for New Jandy AquaLink RS Systems from the year 2007 and newer with software revision R and newer. You have made me a very satisfied customer. If the motor is running, the gear train in the actuator may not be engaged. This means you have water circulating to the spa because the pool cleaner is activated in spa mode. If not what would I need to make sure it works? Look for obstruction or closed valve in system. Do you have a network interface that would work with it or do I have to update revisions? Make sure return eyeball fittings are installed on the wall of the pool. Smart Device. Answered in 4 minutes by: Pool and Spa Expert: poolguy810 poolguy810 : Hello, how can I help you today? No Service Required. Inspect sensor wiring. (above 7.0 PPM) Chlorine output percentage set too high. Replace lid on pump housing. Is the remote displaying error code 6700REV C? Air flow restricted at intake or discharge. 9217 Hwy 290 W STE 200 | Austin, TX 78736 | 512.355.1108 | info@fixyourboard.com . My pool equipment has a jandy one touch controller. After turning Power Center power off and back on now no response from controller at all with and without battery installed. You'll have to find a local store that carries that particular item. There is no debris blocking the impeller and the pressure is still low. Electronic controllers (28 pages) Control Panel Jandy AquaLink RS Owner's Manual. Low or restricted water flow through the heat pump. Replace water temperature sensor. 6. Identify and correct loose wiring connections, or problems with igniter, gas valve, or ignition control. Check cleaning system manual to ensure the system is adjusted according to manufacturers recommendations. Are you dealing with a leak from a solar panel? JVA dip switch test and now fuse is blown. That has gone bad. Not a problem with iAquaLink. But the main concern is stopping the leak. Download or update the iAquaLink app free from the App Store or Google Play. PDF Section 7. Troubleshooting - Pioneer Distribution While the pump is running, try to tighten the union. Fan running slow or premature fan failure. Check for proper clearances around heater and for adequate room ventilation if enclosed. Jandy AquaLink RS4 Indoor Wired Control Board |6891 - Pool Supply Unlimited Posted: 5/14/2017, coolpool Send it in for repair! This unit was a good upgrade for the older one I had that decided it didn't want to connect to wi-fi any longer. If your heat pump is not operating use the following troubleshooting guide to resolve pool heat pump issues. Heat pump will not start, control board display working. That wraps it up! This feature also remains active when the control calls for heat through a remote thermostat. AquaLink PDA - requires revision 6.0 or newer (your PDA remote is still required for programming and scheduling) Check that fan is operating and air is coming out of the top of the heat pump, while short cycling. Posted: 4/11/2020, InyoPools Product Specialist Matt S. Relevant part/model numbers can be found at the bottom of the article. need to know if you can turn Goldline gva-24 manually. Check the suction side piping union. Replace the faulty switch.. If the impeller is still blocked with debris and it is not possible to remove the debris using Steps 2 through 4, the pump will need to be disassembled in order to access the inlet and outlet of the impeller. CORRECTIVE ACTION. This is to insure that water temperature does not go to an abnormally low level due to a possible malfunction of the remote sensor. Control Panel Overview 2.1 Indoor Control Panel The indoor control panel serves as a means of turning equipment on and off, entering programs to run equipment automatically at selected times, and displaying what is going on in the rest of the system. Switch off the circuit breaker to the pump motor. Check our guide on ". Please note, the ePump Controller can not be used in conjunction with a Jandy PDA or OneTouch Controller. Unless you have a spare remote known to be problem-free (read more below the photos), there is no good way to make a home diagnosis of which part is causing the communication breakdown. Turn the heat pump off, then turn circulating pump on for at least one hour to see if the water leak stops. Heat pump does not run and control board display shows HIGH REFRIGERANT PRESSURE. The LCD display will display HIGH H2O on the top line and TEMPERATURE on the bottom line for the duration of the fault condition. Basically the controller on the wall is acting funky. I had the first iteration product and every year when the pool opened had to spend extra $ for the pool service to figure out why it wasn't working. It appears the cable going into the GVA-24 cannot be removed. Turn the pump back on. Broken, split, pinched or disconnected fan/switch tubing. JANDY AQUALINK RS TROUBLESHOOTING MANUAL Pdf Download AquaLink RS systems are fully integratable with home automation systems and feature our patented seasonal adjust technology, which can modify schedules throughout the year for additional energy savings. Back of Power Center: be sure to send the board and panel in for repair. Your IP: B. Unclog the strainer baskets if necessary. My new pool was just finished and the products used were Jandy/Zodiac. Posted: 4/20/2019, Elaine Hughston Have the technician check for loose electrical connections and check the voltage at the pump motor while it is in operation. This is a normal display when the pump is OFF. To engage the gear train, turn the actuator off, then pull up on the Handle and rotate the Handle until it clicks. Locate and correct combustion system sealing beneath burners (see Section 10.3).